Special installation conditions
48 VELUX
4
If the window is wider than the distance between the rafters, it
may be necessary to install trimmers in the rafter construction.
In most cases when installing a trimmer to support a single rafter,
the solution is based on experience. Most often the trimmer has the
same dimensions as the rafters.
Note! Some constructions may require static calculations of the
load capacity of the new trimmer and remaining rafters.
Special conditions to consider:
• A large roof surface above or below the trimmer
• Existing trimmers in the roof construction close to trimmer
• Possible special support conditions of remaining rafters
For combinations of more windows side by side, it is often possible
to adjust window width and frame distances between the windows
in order to retain rafters. This must be determined before ordering
flashings.
Recommended distances to rafters to allow for eective insulation
around the windows.
20-30 mm 20-30 mm
20-30 mm 20-30 mm